# CISWI reductions from L. Sorrels 19jul12, 2:36pm, modified 21nov13: CISWITables_1-5_-_MACT_Floor_Emission_Reductions_October_19,_2011_rmLSadds7-19-12_21nov13.xlsx
# R. Mason computed select SO2 % reductions such that controlled emissions basically matched the unit totals for the quote MACT-floor unquote values
# Analysis confined to larger PM, NOX and SO2 impacts (> 50 tons reductions) and NO NOX or PM sources in NEI2011v6 as large as baseline in original workbook
# Siginficant SO2 sources still found in 2011NEIv1 and are therefore included for control here
# THIS PACKET EXPORTED FROM: /garnet/home/rhc/2011v6/mk_CONTROL_CISWI_2011v6.sas
05081,,SO2,,92.01,100,100,,,Y,R,880811,47419113,,,,"! ARDomtarIndustries, PB1, Energy recovery unit - Solids, Wet Electrostatic Precipitator, General"
05081,,SO2,,92.01,100,100,,,Y,R,880811,47419413,,,,"! ARDomtarIndustries, PB3, Energy recovery unit - Solids, Electrostatic Precipitator"
22031,,SO2,,94.23,100,100,,,Y,R,7225811,80385413,,,,"! LAIPMansfield, 1-78 - No. 1 Power Boiler / EQT005, Energy recovery unit - Solids, Cyclone: Multiple (Multiclone), Electrostatic Precipitator"
22031,,SO2,,92.43,100,100,,,Y,R,7225811,80389813,,,,"! LAIPMansfield, 2-78 - No. 2 Power Boiler, Energy recovery unit - Solids, Cyclone: Multiple (Multiclone), Electrostatic Precipitator"
22069,,SO2,,60.69,100,100,,,Y,R,7226811,80646813,,,,"! LAInternationalPaperRedRiverMill, EQT011 Hogged Fuel Boiler No. 2, Energy recovery unit - Solids, Cyclone: Multiple (Multiclone), Electrostatic Precipitator"